Autoclave testing is performed to evaluate the moisture resistance of packaged solid state devices. Also referred to as steam bomb, autoclave is a highly accelerated test using moisture-condensing or moisture-saturated environments. It utilizes conditions of pressure, temperature and humidity to accelerate moisture penetration into the active circuits inside the package. This moisture generally penetrates in two areas: 1) directly through the encapsulant material or 2) at the sealing junction where the conductors pass into the device.
Autoclave should be performed whenever a new package is being introduced OR whenever a package has undergone a redesign that has required material changes, such as a change in molding compound, die attach adhesive or perhaps die passivation. It should also be done when there have been mechanical changes such as a change in die size or a change in leadframe dimensions. Autoclave testing is not to be regarded as being the same as “HAST” (highly accelerated stress test).

|